Plate Cells Series F-FA-FS
& Hermetically Sealed Series FM-FAM-FSM

Features
  • Hermetically Sealed Packages
  • Room Temperature Operation
  • Custom Wavelength Response
  • Custom Test
  • Hybrid Amplifiers
  • 2 Year Warranty
  • Customized Filters Available
  • Custom Packages
How To Order
    Select the proper electrical type (F; FM) and match it with the proper mechanical and package code number. Example: FM-1-5, FM-5-8. The active areas listed are considered standard sizes. Special sizes are available upon request.

 

 

 


Electrical Specifications

Test Conditions at 25°C - Typical F & FM FA & FAM FS & FSM
D* (Pk.,1000,1) x 109 1.0 - 3.0 3.0 - 6.0 >6.0
Wavelength Cut-off - Microns 4.5 - 5.0 4.5 - 5.0 4.5 - 5.0
Peak Wavelength Response - Microns 3.8 - 4.3 3.8 - 4.3 3.8 - 4.3
Time Constant - Microseconds 1 - 3 1 - 3 1 - 3
Resistance - Megohms .1 - 4 .1 - 4 .1 - 4

Active Area Specifications

Code
Number
Active Area Bias Voltage Typical VW-1 Package
Size
Inches mm Typical Maximum
1 .040 1 50 100 6,000 TO-5 & TO-46
2 .080 2 100 200 3,000 TO-5
3 .120 3 150 300 2,000 TO-5
5 .200 5 250 500 1,200 TO-8
10 .400 10 500 1000 600 TO-3

Mechanical Specifications

TO-46
TO-46

TO-5
TO-5

TO-8
TO-8

TO-3
TO-3

If you have questions about our products, please contact us using this form.