Lead Sulfide Thermoelectrically Cooled Detectors
Series D-D2-D21

Features
  • Hermetically Sealed Packages
  • Custom Wavelength Response
  • Custom Test Procedure
  • Custom Design Services
  • 2 Year Warranty
  • Filters Available
How To Order
    Select the proper electrical type (D, D21), and match it with the proper mechanical and package code number. Example: D-3-8, D2-1-37, D21-3-8. The active areas listed are considered standard sizes. Special sizes are available upon request.

 

 

 


Electrical Specifications

Test Conditions at 25° C -Typical D D2 D21**
D* (Pk.,600,1) x 1011 1.5 2.5 2.8
Wavelength Cut-off - Microns 3.1 3.2 3.3
Peak Wavelength Response - Microns 2.5 2.5 2.5
Time Constant - Milliseconds 1-2.5 1-2.5 1-2.5
Resistance - Megohms .5-10 .5-10 .5- 5
Operating Temperature - °C -20 -30 -45
Cooler Power - Volts DC/Amps .8V/1.8A .8V/1.4A 2.0V/1.4A

Active Area Specifications

Code
Number
Active Area Bias Voltage Typical VW-1X15
Responsivity
Package
Size
Inches mm Typical Maximum -20 -30 -45
1 .040 1 50 100 6.0 9.0 13.0 TO-5-37-8-66
2 .080 2 100 200 3.0 4.5 6.5 TO-5-37-8-66
3 .120 3 150 300 2.5 3.5 4.5 TO-5-37-8-66
5 .200 5 250 500 1.2 2.0 3.0 TO-8-66
10 .400 10 500 1000 .6 1.0 1.5 TO-3

Mechanical Specifications

If you have questions about our products, please contact us using this form.