Lead Sulfide Plate Cells Series
A-B-C & Hermetically Sealed Series AM-BM-CM

Features
  • Hermetically Sealed Packages
  • Room Temperature Operation
  • Custom Wavelength Response
  • Custom Test Procedure
  • Hybrid Amplifiers
  • 2 Year Warranty
  • Filters Available
How To Order
    Select the proper electrical type (A,BM) and, match it with the proper mechanical and package code number. Example: A- 1, BM-5-8. The active areas listed are considered standard sizes. Special sizes are available upon request. Series C can be gridded for low resistance. Plate cells can be supplied with or without leads.

 

 

 


Electrical Specifications

Test Conditions at 25°C - Typical A & AM B & BM C & CM
D* (Pk.,600,1) x 1011 .5-1.2 .5-1.2 .5-1.2
Wavelength Cut-off - Microns 3.0 3.0 2.7
Peak Wavelength Response - Microns 2.5 2.5 2.2
Time Constant - Microseconds <100 100-300 >300
Resistance - Megohms .2-2.0 .2-2.0 .5-10

Active Area Specifications

Code
Number
Active Area Bias Voltage Typical  VW-1
Responsivity
Package
Size
Inches mm Typical Maximum
.25 .010 .25 10 20 1.0x106 TO-5 & TO-46
.5 .020 .5 20 40 6.0x105 TO-5 & TO-46
1 .040 1 50 100 3.0x105 TO-5 & TO-46
2 .080 2 100 200 1.5x105 TO-5
3 .120 3 150 300 1.0x105 TO-5
5 .200 5 250 500 6.0x104 TO-8
10 .400 10
500
1000 3.0x104 TO-3

Mechanical Specifications

TO-46
TO-46

TO-5
TO-5

TO-8
TO-8

TO-3
TO-3

If you have questions about our products, please contact us using this form.