Features
- Hermetically Sealed Packages
- Custom Wavelength Response
- Custom Test Procedure
- Custom Design Services
- 2 Year Warranty
- Filters Available
|
How To Order Select
the proper electrical type (D, D21), and match it with the proper mechanical and package
code number. Example: D-3-8, D2-1-37, D21-3-8. The active areas listed are considered
standard sizes. Special sizes are available upon request. |
Electrical Specifications
| Test Conditions at 25° C -Typical |
D |
D2 |
D21** |
| D* (Pk.,600,1) x 1011 |
1.5 |
2.5 |
2.8 |
| Wavelength Cut-off - Microns |
3.1 |
3.2 |
3.3 |
| Peak Wavelength Response - Microns |
2.5 |
2.5 |
2.5 |
| Time Constant - Milliseconds |
1-2.5 |
1-2.5 |
1-2.5 |
| Resistance - Megohms |
.5-10 |
.5-10 |
.5- 5 |
| Operating Temperature - °C |
-20 |
-30 |
-45 |
| Cooler Power - Volts DC/Amps |
.8V/1.8A |
.8V/1.4A |
2.0V/1.4A |
NOTE: 3-6 Stage Thermoelectric Coolers and Vacuum LN Dewars also
available. Contact NEP for further details.
**TO-8, TO-66 or TO-3 packages only.
Active Area Specifications
Code
Number |
Active Area |
Bias Voltage |
Typical VW-1X105
Responsivity |
Package
Size |
| Inches |
mm |
Typical |
Maximum |
-20 |
-30 |
-45 |
| 1 |
.040 |
1 |
50 |
100 |
6.0 |
9.0 |
13.0 |
TO-5-37-8-66 |
| 2 |
.080 |
2 |
100 |
200 |
3.0 |
4.5 |
6.5 |
TO-5-37-8-66 |
| 3 |
.120 |
3 |
150 |
300 |
2.5 |
3.5 |
4.5 |
TO-5-37-8-66 |
| 5 |
.200 |
5 |
250 |
500 |
1.2 |
2.0 |
3.0 |
TO-8-66 |
| 10 |
.400 |
10 |
500 |
1000 |
.6 |
1.0 |
1.5 |
TO-3 |
Mechanical Specifications