Features
- Hermetically Sealed Packages
- Room Temperature Operation
- Custom Wavelength Response
- Custom Test Procedure
- Hybrid Amplifiers
- 2 Year Warranty
- Filters Available
|
How To Order Select
the proper electrical type (A,BM) and, match it with the proper mechanical and package
code number. Example: A- 1, BM-5-8. The active areas listed are considered standard sizes.
Special sizes are available upon request. Series C can be gridded for low resistance.
Plate cells can be supplied with or without leads. |
Electrical Specifications
| Test Conditions at 25°C - Typical |
A & AM |
B & BM |
C & CM |
| D* (Pk.,600,1) x 1011 |
.5-1.2 |
.5-1.2 |
.5-1.2 |
| Wavelength Cut-off - Microns |
3.0 |
3.0 |
2.7 |
| Peak Wavelength Response - Microns |
2.5 |
2.5 |
2.2 |
| Time Constant - Microseconds |
<100 |
100-300 |
>300 |
| Resistance - Megohms |
.2-2.0 |
.2-2.0 |
.5-10 |
Active Area Specifications
Code
Number |
Active Area |
Bias Voltage |
Typical VW-1
Responsivity |
Package
Size |
| Inches |
mm |
Typical |
Maximum |
| .25 |
.010 |
.25 |
10 |
20 |
1.0x106 |
TO-5 & TO-46 |
| .5 |
.020 |
.5 |
20 |
40 |
6.0x105 |
TO-5 & TO-46 |
| 1 |
.040 |
1 |
50 |
100 |
3.0x105 |
TO-5 & TO-46 |
| 2 |
.080 |
2 |
100 |
200 |
1.5x105 |
TO-5 |
| 3 |
.120 |
3 |
150 |
300 |
1.0x105 |
TO-5 |
| 5 |
.200 |
5 |
250 |
500 |
6.0x104 |
TO-8 |
| 10 |
.400 |
10 |
500 |
1000 |
3.0x104 |
TO-3 |
Mechanical Specifications